Shopping Cart
Quick view
Login
Search for products on our site
See more

For Special Discount Prices Text or Call Now! (630) 888-2888

BLT M1000Vet Biolight Multi-Parameter Veterinary Monitor
On Sale

BLT M1000Vet Biolight Multi-Parameter Veterinary Monitor

  • -$-1,499.99
  • Regular price $1,499.99

    M1000Vet is a high quality monitor made by Biolight. Very accurate and reliable monitor that is compact, touchscreen, and battery powered. Comes ready to work with the veterinary accessories needed. Weighs only a few pounds, and doesn't take up much space.

    Standard configuration 3/5 Lead ECG, HR, RESP, NIBP, SpO2, PR, TEMP, Rechargeable lithium ion battery.

     
    • 8” TFT LCD touch screen 
    • Lightweight and compact portable design 
    • Standard parameters including 3/5 leads ECG, HR, RESP, NIBP, SpO2, PR, TEMP 
    • Triple and Multi-level Sound/Light/Screen alarm 
    • Large capability battery with over 6 hours continuous usage 
    • 168 hours trend data storage 
    • 1000 groups NIBP measurement review
     
    Physical & Power specifications  
    Dimension: 220mm (H)×180mmW)×90mm(D) 
    Weight: <2 kg 
    Power Voltage: AC 100V-240V 50Hz/60Hz 
    Input current: 1.5A-0.7A
    Battery 
    Type: 11.1VDC/2200mAh, Rechargeable Lithium ion battery 
    Operating time: Under the normal use and full charge: ≥6 hours 
    Indicator of battery capability: With
    Display
    Size: 8″ Color TFT LCD touch screen 
    Resolution: 800×600 pixels
    Data Storage
    Trend data: 168 Hours 
    NIBP measurement review: 1000 Groups 
    Alarm Events: 128 Groups 
    ARR event: 128 Groups
    ECG
    Lead Mode: 3/5 leads ECG input 
    Lead selection: I, II, III, aVR, aVL, aVF, V 
    Gain: 2.5 mm/mV(×0.25), 5 mm/mV(×0.5), 
     10 mm/mV(×1),20 mm/mV(×2) ,  
     40 mm/mV(×4) , Auto 
    Input impedance: ≥5.0 MΩ 
    Animal leakage current: < 10 uA 
    CMRR : Diagnostic mode ≥ 89 dB
    Monitor mode ≥ 105 dB 
    Surgery mode ≥ 105 dB 
    Baseline recovery: Monitor mode: ≤ 3 s; 
    Surgery mode: ≤ 1 s 
    Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s
    HR 
    Measurement Range: Large animal: 10 bpm to 300 bpm 
    Normal and small animal: 10 bpm to 350 bpm 
    Accuracy: ±1% or ±1 bpm, whichever is greater
    RESP 
    Method: Thoracic impedance 
    Measuring impedance range: 0.2Ω ~3Ω 
    Accuracy: ±2 rpm
    NIBP 
    Measurement way: Automatic Oscillometry 
    Measurement range(mmHg): SYS 30~270 mmHg 
     DIA 10~220 mmHg  
     Map 20~235 mmHg 
    (Large animal, normal and small animal have different measurement range) 
    Pressure Accuracy: Static: ±3 mmHg 
    Clinic: Average error: ±5 mmHg, 
    standard deviation: ≤8 mmHg 
    Unit: mmHg, kPa 
    Cuff pressure range: 0 mmHg ~ 280 mmHg
    Initial inflation pressure:
    Large animal default: 160 mmHg 
    Mid animal default: 130 mmHg 
    Small animal default: 75 mm 
    Overpressure Protection(Hardware and software double protections): 
    Large animal: (297±3) mmHg Normal animal: (147±3) mmHg 
    Small animal: (252±3) mmHg 
    Alarm Indication: Three levels of alarming: Audible-visual alarming 
    Alarming with blinked data and parameters Text prompts 
    Work mode: Large animal: Single, Cycle, STAT 
    Normal animal: Single, Cycle, STAT 
    Small animal: Single, Cycle
    BLT SpO2 
    Measurement Range: 0%~100% 
    Resolution: 1% 
    Accuracy: At 70~100%, ±2% At 0~69%, unspecified 
    Alarm range: 85% to 100%, high/low limit can be adjusted continuously
    Average time: Normal:8s, slow: 16s,fast: 4s 
    Anti-interference: Anti-interference of movement Anti-interference of electrocautery unit 
    Resisting low perfusion capability 
    Pitch Tone: With
    PR 
    Measurement Range: 20~250 bpm 
    Resolution:1 bpm Accuracy: ±1% or ±1 bpm, whichever is greater 
    Alarm range: 0 bpm~300 bpm, high/low limit can be adjusted continuously 
    Recovery time after defibrillation: <10s
    TEMP 
    Measurement way: Thermal resistance way 
    Measurement Range: 0.0~50.0℃ (32℉~122℉) 
    Unit : Celsius (℃), Fahrenheit (℉) 
    Resolution: 0.1℃ 
    Accuracy: At 45.1~50.0℃, ±0.3℃ (including the probe) 
    At 25.0~45.0℃, ±0.2℃ (including the probe) 
    At 0.0~24.9℃, ±0.3℃ (including the probe)