Hemodynamics is seen with great detail due to the B-Flow Color which allows you to recognize the different flow variations while maintaining high frame rates.
Remarkable temporal and spatial resolution when scanning vessels to the imaging blood reflectors.
Dynamic, portable, and excellent images.
Harmonics increase the resolution and cystic clarity that incorporates coded harmonics with Phase Inversion Harmonics.
Tissues and border differentiation are improved by the CrossXBeam. In addition, the real-time spatial compounds the acquisition and processing.
The Raw Data promptly stores the data of the image chain to allow the best flexibility during post-processing and analysis.
High frames rates are maintained by the DualBeam despite using high line density, even in abnormal settings. Temporal resolution is elevated in the fast-flow cardiac and vascular studies.
The clarity of the organs and lesions are magnified by the Speckle Reduction Imaging (SRI). The high-definition contrast resolution suppresses speckle artifact while preserving true tissue architecture.
No matter the size or difficulty of the patient every exam receives a clear and precise image. The new ceramic materials in the Single-crystal transducers expands the bandwidth and enhances the sensitivity to deliver excellent cardiac performance.
Real-time 4D imaging achieves and produces volumetric images that envisions the multi-planar anatomical views.
System Details
Depth: 640 mm
Monitor: 17-inch TFT LCD
Height: 1360 mm
Weight: approx. 80 kg (176 lb.)
Width: 430 mm
Operations
Gynecological
Vascular
Breast
Endocavity
Transesophageal
Obstetrical
Cardiac
Small Parts and Superficial
Pediatric and Neonatal
Abdominal
Intraoperative
Transcranial
Urological
Musculoskeletal
Transducer Types
Linear Array
Volume ‘4D’
Convex Array
TEE Multiplane Sector Array
Sector Phased Array
Single CW (Pencil)
Bi-plane Microconvex Array
Microconvex Array
Operating Modes
M-Mode
PW Doppler w/High PRF
Anatomical M-Color Mode (option)
Coded Contrast Imaging (option)
Tissue Velocity Imaging (TVI) Mode (option)
4D Real time (option)
Coded Harmonic Imaging
Power Doppler Imaging (PDI) with Directional Map
Anatomical M-Mode (option)
B-Flow Color Mode (option)
PFD Mode (option)
3D Static (option)
Elastography (option)
B-Mode
Color Flow Mode (CFM)
M-Color Flow Mode
B-Flow Mode (option)
CW Doppler Mode (option)
3D/4D Volume Modes (option)
Optional Transducers
GE 8C – 4-11MHz, Microconvex
GE 3CRF – 2-4MHz, Microconvex
GE 9L – 3-10MHz, Linear
GE T739 – 4-12MHz, Linear (Intraoperative)
GE 3Sp – 1.5-5.5MHz, Phased Array Sector
GE 5S – 2-5MHz, Phased Array Sector
GE ERB – 3-11MHz, Bi-plane Intracavity
GE 4DE7C – 4-11MHz, Convex Volume
GE P6D – 5.0MHz, Non-Imaging Single CW Doppler Pencil
GE 5CS – 2-6MHz, Convex
GE E8C – 4-11MHz, Microconvex (Endocavity)
GE BE9CS – 4-11MHz, Bi-plane Microconvex
GE 11L – 5-13MHz, Linear
GE 8L – 4-11MHz, Linear
GE P2D – 2.0MHz, Non-Imaging Single CW Doppler Pencil
GE 4C – 1.4-5.0MHz, Convex
GE 4D8C – 4-11MHz, Microconvex Volume
GE 4D5C-L – 3-7MHz, Convex Volume
GE E8CS – 4-11MHz, Microconvex
GE 4D3C-L – 2-5MHz, Convex Volume
GR 6Tc – 3-7MHz, Multiplane Transesophageal Phased Array Sector