1.1 Scope of application

It is applicable to accurate, constant and continuous intravenous infusion in Veterinary institutions.

1.2 Technical Parameters
IV Set Options /Size: Open System for common widely-used brand of 10d/ml,15d/ml,20d/ml,60d/ml (3.4mm~4.5mm), Also can be customized for dedicated IV set

Infusion Mode: 

Infusion mode

Description

Operation

Remark

Volume mode(ml/h)

Choose mode needed

n  VTBI/time/rate

n  VTBI / rate

n  VTBI / time

n  time / rate

n  Simple rate mode

n Rate:0.1 ~1200ml/h

n VTBI:0~9999ml

n Time:1min~99h59min

n VOL:0.1~999.9ml

Drop mode(Drops/min)

This European version does not have this feature

Choose mode needed

n  VTBI / time / rate

n  VTBI / rate

n  VTBI / time

n  time / rate

n  Simple rate mode

n Rate: 1d/min ~ 400d/min

(10d/ml,15d/ml,20d/ml)

n Rate: 1d/min ~ 150d/min

(60 d /ml)

n VTBI:0~9999ml

n Time:1min~99h59min

n VOL:0.1~999.9ml

Program mode

Choose mode needed

n VTBI / rate

n Pause time

n 8 stages of programming

n Can stop infusion to program

Weight mode

Choose mode needed

n dose/weight

 

Drug Library mode

Choose mode needed

n dose/ rate

n rate

n Can import drug library

n 50 kinds of drugs inside machine

Bolus

n Automatic

n VTBI / rate

n Rate:0.1~1200ml/h adjustable

n VTBI:1~9999ml adjustable

n Default 600ml/h,2ml

n Manual

n VTBI / rate

KVO

n Opens automatically as infusion is completed 

n Whether displays KVO volume and rate setting

n 1~20ml/h adjustable

n 1ml/h default

 

 

KVO: Adjustable from 1ml/h - 20ml/h

Infusion Rate:  20 d/ml IV set: 0.1~1200ml/h; 1.0~400d/min

                         60 d/ml IV set :0.1~150ml/h;  1.0~150d/min

                         0.1 ml/h increments; 1d/min increments

Bolus: Two way: 1) Short Press Bolus Key to into setup menu (adjustable from 1.0~1200ml/h) 

                           2) Long Press Bolus key to automatic running last time setup rate.

Accuracy:  Infusion Drop rate accuracy: ±2% (after drops 150 drips)

Infusion Flow rate accuracy: ±5% (using calibrated standard PVC IV set)

Occlusion Pressure:  Up position: -100mmhg~-300mmgh;  ±10%; 5 level option

Down position: 300mmhg~1200mmhg;±10%; 5 level option

Preset Volume Range: 1-9999ml

Purge: 600ml/h

Bubble Detection: Detected by ultrasonic sensor with adjust setting , 50μL ~ 800μL.

Alarm: Bubble, Door open, Finish, Pause overtime, Leakage, Empty, low Battery, Battery damage, Motor reverse, IV Set size Error, Pressure failure, Motor failure, Flow Rate Error, Fluid Warmer failure, Down Occlusion, Up Occlusion,internal communication fail

CPU: Dual

Lock Key: By manual lock to avoid misuse

Programmable: Infusion can be programmed in 8 segments

Library : Built-in 49 common drugs, could up to 100 kinds of drug

History Record: 1500 event records, 200 modified records;

Records can be exported in LAN

Piggyback: User changes parameters without switching off
Fluid Warmer(optional): Relieve uncomfortable such as pain, vessel convulsion, shiver when transfer cold fluid

 

1.3 Product specifications

Power dissipation: 25VA

Display: Color LCD
Power supply: AC100-240V, 50Hz/60Hz (not recommended to share an outlet with other electrical equipment, household power outlet is applicable.)
Battery: Ni-MH battery, DC9.6V, 2000mAh (after fully charged, it can last about 6 hours at 25ml/h.)

Protection: Class I, Type CF, IPX4, with internal power supply

Net weight: 2.0Kg

Dimensions: 130mm × 120mm × 195mm (not including protrusions)

 
1.4 Work environment

Operating temperature: +5 ℃ ~ +40 ℃

Relative humidity: 20~90% (Non-condensing) 

Atmospheric pressure: 70kPa ~106kPa

BUY NOW!

Payment

We accept payment by any of the following methods:

PayPal

 

Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner!

Shipping

We offer FREE shipping on all orders in the USA!


Your item has an extended handling time and delivery estimate is greater than 10 working days of receiving payment (Monday-Friday) after which you should expect to receive it as soon as possible.


In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement.

If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not.


You can return a product for up to 14 days from the date you purchased it.


Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt.

High Quality
Best Pricing
Fast Shipping
1.1 Scope of application It is applicable to accurate, constant and continuous intravenous infusion in Veterinary institutions. 1.2 Technical Parameters IV Set Options /Size: Open System for common widely-used brand of 10d/ml,15d/ml,20d/ml,60d/ml (3.4mm~4.5mm), Also can be customized for dedicated IV set Infusion Mode: Infusion mode Description Operation Remark Volume mode(ml/h) Choose mode needed n VTBI/time/rate n VTBI / rate n VTBI / time n time / rate n Simple rate mode n Rate:0.1 ~1200ml/h n VTBI:0~9999ml n Time:1min~99h59min n VOL:0.1~999.9ml Drop mode(Drops/min) This European version does not have this feature Choose mode needed n VTBI / time / rate n VTBI / rate n VTBI / time n time / rate n Simple rate mode n Rate: 1d/min ~ 400d/min (10d/ml,15d/ml,20d/ml) n Rate: 1d/min ~ 150d/min (60 d /ml) n VTBI:0~9999ml n Time:1min~99h59min n VOL:0.1~999.9ml Program mode Choose mode needed n VTBI / rate n Pause time n 8 stages of programming n Can stop infusion to program Weight mode Choose mode needed n dose/weight Drug Library mode Choose mode needed n dose/ rate n rate n Can import drug library n 50 kinds of drugs inside machine Bolus n Automatic n VTBI / rate n Rate:0.1~1200ml/h adjustable n VTBI:1~9999ml adjustable n Default 600ml/h,2ml n Manual n VTBI / rate KVO n Opens automatically as infusion is completed n Whether displays KVO volume and rate setting n 1~20ml/h adjustable n 1ml/h default KVO: Adjustable from 1ml/h - 20ml/h Infusion Rate: 20 d/ml IV set: 0.1~1200ml/h; 1.0~400d/min 60 d/ml IV set :0.1~150ml/h; 1.0~150d/min 0.1 ml/h increments; 1d/min increments Bolus: Two way: 1) Short Press Bolus Key to into setup menu (adjustable from 1.0~1200ml/h) 2) Long Press Bolus key to automatic running last time setup rate. Accuracy: Infusion Drop rate accuracy: ±2% (after drops 150 drips) Infusion Flow rate accuracy: ±5% (using calibrated standard PVC IV set) Occlusion Pressure: Up position: -100mmhg~-300mmgh; ±10%; 5 level option Down position: 300mmhg~1200mmhg;±10%; 5 level option Preset Volume Range: 1-9999ml Purge: 600ml/h Bubble Detection: Detected by ultrasonic sensor with adjust setting , 50μL ~ 800μL. Alarm: Bubble, Door open, Finish, Pause overtime, Leakage, Empty, low Battery, Battery damage, Motor reverse, IV Set size Error, Pressure failure, Motor failure, Flow Rate Error, Fluid Warmer failure, Down Occlusion, Up Occlusion,internal communication fail CPU: Dual Lock Key: By manual lock to avoid misuse Programmable: Infusion can be programmed in 8 segments Library : Built-in 49 common drugs, could up to 100 kinds of drug History Record: 1500 event records, 200 modified records; Records can be exported in LAN Piggyback: User changes parameters without switching off Fluid Warmer(optional): Relieve uncomfortable such as pain, vessel convulsion, shiver when transfer cold fluid 1.3 Product specifications Power dissipation: 25VA Display: Color LCD Power supply: AC100-240V, 50Hz/60Hz (not recommended to share an outlet with other electrical equipment, household power outlet is applicable.) Battery: Ni-MH battery, DC9.6V, 2000mAh (after fully charged, it can last about 6 hours at 25ml/h.) Protection: Class I, Type CF, IPX4, with internal power supply Net weight: 2.0Kg Dimensions: 130mm × 120mm × 195mm (not including protrusions) 1.4 Work environment Operating temperature: +5 ℃ ~ +40 ℃ Relative humidity: 20~90% (Non-condensing) Atmospheric pressure: 70kPa ~106kPa

KeeboVet​​​​​​​

High Quality
Best Pricing
Fast Shipping
Vet Infusion Pump, With Heater, European Standard, TUV CE & ISO13485, RoHS

1.1 Scope of application

It is applicable to accurate, constant and continuous intravenous infusion in Veterinary institutions.

1.2 Technical Parameters
IV Set Options /Size: Open System for common widely-used brand of 10d/ml,15d/ml,20d/ml,60d/ml (3.4mm~4.5mm), Also can be customized for dedicated IV set

Infusion Mode: 

Infusion mode

Description

Operation

Remark

Volume mode(ml/h)

Choose mode needed

n  VTBI/time/rate

n  VTBI / rate

n  VTBI / time

n  time / rate

n  Simple rate mode

n Rate:0.1 ~1200ml/h

n VTBI:0~9999ml

n Time:1min~99h59min

n VOL:0.1~999.9ml

Drop mode(Drops/min)

This European version does not have this feature

Choose mode needed

n  VTBI / time / rate

n  VTBI / rate

n  VTBI / time

n  time / rate

n  Simple rate mode

n Rate: 1d/min ~ 400d/min

(10d/ml,15d/ml,20d/ml)

n Rate: 1d/min ~ 150d/min

(60 d /ml)

n VTBI:0~9999ml

n Time:1min~99h59min

n VOL:0.1~999.9ml

Program mode

Choose mode needed

n VTBI / rate

n Pause time

n 8 stages of programming

n Can stop infusion to program

Weight mode

Choose mode needed

n dose/weight

 

Drug Library mode

Choose mode needed

n dose/ rate

n rate

n Can import drug library

n 50 kinds of drugs inside machine

Bolus

n Automatic

n VTBI / rate

n Rate:0.1~1200ml/h adjustable

n VTBI:1~9999ml adjustable

n Default 600ml/h,2ml

n Manual

n VTBI / rate

KVO

n Opens automatically as infusion is completed 

n Whether displays KVO volume and rate setting

n 1~20ml/h adjustable

n 1ml/h default

 

 

KVO: Adjustable from 1ml/h - 20ml/h

Infusion Rate:  20 d/ml IV set: 0.1~1200ml/h; 1.0~400d/min

                         60 d/ml IV set :0.1~150ml/h;  1.0~150d/min

                         0.1 ml/h increments; 1d/min increments

Bolus: Two way: 1) Short Press Bolus Key to into setup menu (adjustable from 1.0~1200ml/h) 

                           2) Long Press Bolus key to automatic running last time setup rate.

Accuracy:  Infusion Drop rate accuracy: ±2% (after drops 150 drips)

Infusion Flow rate accuracy: ±5% (using calibrated standard PVC IV set)

Occlusion Pressure:  Up position: -100mmhg~-300mmgh;  ±10%; 5 level option

Down position: 300mmhg~1200mmhg;±10%; 5 level option

Preset Volume Range: 1-9999ml

Purge: 600ml/h

Bubble Detection: Detected by ultrasonic sensor with adjust setting , 50μL ~ 800μL.

Alarm: Bubble, Door open, Finish, Pause overtime, Leakage, Empty, low Battery, Battery damage, Motor reverse, IV Set size Error, Pressure failure, Motor failure, Flow Rate Error, Fluid Warmer failure, Down Occlusion, Up Occlusion,internal communication fail

CPU: Dual

Lock Key: By manual lock to avoid misuse

Programmable: Infusion can be programmed in 8 segments

Library : Built-in 49 common drugs, could up to 100 kinds of drug

History Record: 1500 event records, 200 modified records;

Records can be exported in LAN

Piggyback: User changes parameters without switching off
Fluid Warmer(optional): Relieve uncomfortable such as pain, vessel convulsion, shiver when transfer cold fluid

 

1.3 Product specifications

Power dissipation: 25VA

Display: Color LCD
Power supply: AC100-240V, 50Hz/60Hz (not recommended to share an outlet with other electrical equipment, household power outlet is applicable.)
Battery: Ni-MH battery, DC9.6V, 2000mAh (after fully charged, it can last about 6 hours at 25ml/h.)

Protection: Class I, Type CF, IPX4, with internal power supply

Net weight: 2.0Kg

Dimensions: 130mm × 120mm × 195mm (not including protrusions)

 
1.4 Work environment

Operating temperature: +5 ℃ ~ +40 ℃

Relative humidity: 20~90% (Non-condensing) 

Atmospheric pressure: 70kPa ~106kPa

BUY NOW!

Payment

We accept payment by any of the following methods:

PayPal

 

Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner!

Shipping

We offer FREE shipping on all orders in the USA!


Your item has an extended handling time and delivery estimate is greater than 10 working days of receiving payment (Monday-Friday) after which you should expect to receive it as soon as possible.


In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement.

If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not.


You can return a product for up to 14 days from the date you purchased it.


Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt.

High Quality
Best Pricing
Fast Shipping

1.1 Scope of application

It is applicable to accurate, constant and continuous intravenous infusion in Veterinary institutions.

1.2 Technical Parameters
IV Set Options /Size: Open System for common widely-used brand of 10d/ml,15d/ml,20d/ml,60d/ml (3.4mm~4.5mm), Also can be customized for dedicated IV set

Infusion Mode: 

Infusion mode

Description

Operation

Remark

Volume mode(ml/h)

Choose mode needed

n  VTBI/time/rate

n  VTBI / rate

n  VTBI / time

n  time / rate

n  Simple rate mode

n Rate:0.1 ~1200ml/h

n VTBI:0~9999ml

n Time:1min~99h59min

n VOL:0.1~999.9ml

Drop mode(Drops/min)

This European version does not have this feature

Choose mode needed

n  VTBI / time / rate

n  VTBI / rate

n  VTBI / time

n  time / rate

n  Simple rate mode

n Rate: 1d/min ~ 400d/min

(10d/ml,15d/ml,20d/ml)

n Rate: 1d/min ~ 150d/min

(60 d /ml)

n VTBI:0~9999ml

n Time:1min~99h59min

n VOL:0.1~999.9ml

Program mode

Choose mode needed

n VTBI / rate

n Pause time

n 8 stages of programming

n Can stop infusion to program

Weight mode

Choose mode needed

n dose/weight

 

Drug Library mode

Choose mode needed

n dose/ rate

n rate

n Can import drug library

n 50 kinds of drugs inside machine

Bolus

n Automatic

n VTBI / rate

n Rate:0.1~1200ml/h adjustable

n VTBI:1~9999ml adjustable

n Default 600ml/h,2ml

n Manual

n VTBI / rate

KVO

n Opens automatically as infusion is completed 

n Whether displays KVO volume and rate setting

n 1~20ml/h adjustable

n 1ml/h default

 

 

KVO: Adjustable from 1ml/h - 20ml/h

Infusion Rate:  20 d/ml IV set: 0.1~1200ml/h; 1.0~400d/min

                         60 d/ml IV set :0.1~150ml/h;  1.0~150d/min

                         0.1 ml/h increments; 1d/min increments

Bolus: Two way: 1) Short Press Bolus Key to into setup menu (adjustable from 1.0~1200ml/h) 

                           2) Long Press Bolus key to automatic running last time setup rate.

Accuracy:  Infusion Drop rate accuracy: ±2% (after drops 150 drips)

Infusion Flow rate accuracy: ±5% (using calibrated standard PVC IV set)

Occlusion Pressure:  Up position: -100mmhg~-300mmgh;  ±10%; 5 level option

Down position: 300mmhg~1200mmhg;±10%; 5 level option

Preset Volume Range: 1-9999ml

Purge: 600ml/h

Bubble Detection: Detected by ultrasonic sensor with adjust setting , 50μL ~ 800μL.

Alarm: Bubble, Door open, Finish, Pause overtime, Leakage, Empty, low Battery, Battery damage, Motor reverse, IV Set size Error, Pressure failure, Motor failure, Flow Rate Error, Fluid Warmer failure, Down Occlusion, Up Occlusion,internal communication fail

CPU: Dual

Lock Key: By manual lock to avoid misuse

Programmable: Infusion can be programmed in 8 segments

Library : Built-in 49 common drugs, could up to 100 kinds of drug

History Record: 1500 event records, 200 modified records;

Records can be exported in LAN

Piggyback: User changes parameters without switching off
Fluid Warmer(optional): Relieve uncomfortable such as pain, vessel convulsion, shiver when transfer cold fluid

 

1.3 Product specifications

Power dissipation: 25VA

Display: Color LCD
Power supply: AC100-240V, 50Hz/60Hz (not recommended to share an outlet with other electrical equipment, household power outlet is applicable.)
Battery: Ni-MH battery, DC9.6V, 2000mAh (after fully charged, it can last about 6 hours at 25ml/h.)

Protection: Class I, Type CF, IPX4, with internal power supply

Net weight: 2.0Kg

Dimensions: 130mm × 120mm × 195mm (not including protrusions)

 
1.4 Work environment

Operating temperature: +5 ℃ ~ +40 ℃

Relative humidity: 20~90% (Non-condensing) 

Atmospheric pressure: 70kPa ~106kPa

Go to full site